15 resultados para 090300 BIOMEDICAL ENGINEERING

em Indian Institute of Science - Bangalore - Índia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The literature contains many examples of digital procedures for the analytical treatment of electroencephalograms, but there is as yet no standard by which those techniques may be judged or compared. This paper proposes one method of generating an EEG, based on a computer program for Zetterberg's simulation. It is assumed that the statistical properties of an EEG may be represented by stationary processes having rational transfer functions and achieved by a system of software fillers and random number generators.The model represents neither the neurological mechanism response for generating the EEG, nor any particular type of EEG record; transient phenomena such as spikes, sharp waves and alpha bursts also are excluded. The basis of the program is a valid ‘partial’ statistical description of the EEG; that description is then used to produce a digital representation of a signal which if plotted sequentially, might or might not by chance resemble an EEG, that is unimportant. What is important is that the statistical properties of the series remain those of a real EEG; it is in this sense that the output is a simulation of the EEG. There is considerable flexibility in the form of the output, i.e. its alpha, beta and delta content, which may be selected by the user, the same selected parameters always producing the same statistical output. The filtered outputs from the random number sequences may be scaled to provide realistic power distributions in the accepted EEG frequency bands and then summed to create a digital output signal, the ‘stationary EEG’. It is suggested that the simulator might act as a test input to digital analytical techniques for the EEG, a simulator which would enable at least a substantial part of those techniques to be compared and assessed in an objective manner. The equations necessary to implement the model are given. The program has been run on a DEC1090 computer but is suitable for any microcomputer having more than 32 kBytes of memory; the execution time required to generate a 25 s simulated EEG is in the region of 15 s.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A diagnostic system for ECG rhythm monitoring based on syntactic approaches to pattern recognition is presented here. The method proposed exploits the difference in shape and structure between arrhythmic and normal ECG patterns to generate distinctly different descriptions in terms of a chosen set of primitives. A given frame of signal is first approximated piecewise linearly into a set of line segments which are completely specified in terms of their length and slope values. The slope values are quantized into seven distinct levels and a unit-length line segment with a slope value in each of these levels is coded as a slope symbol. Seven such slope symbols constitute the set of primitives. The given signal is represented as a string of such symbols based on the length and angle of the line segments approximating the signal. Context-free languages are used for describing the classes of abnormal and normal ECG patterns considered here. Analysis of actual ECG data shows efficiency comparable with that of existing methods and a saving in processing time.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fourier shape descriptors of vectorcardiograms have been proposed for cardiac rhythm analysis. The technique characterizes the differences in shape and size of the normal and abnormal vectorcardiograms. The specific abnormalities considered are premature ventricular contractions (PVC's) and supraventricular premature contractions (SVPC's).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Effective usage of image guidance by incorporating the refractive index (RI) variation in computational modeling of light propagation in tissue is investigated to assess its impact on optical-property estimation. With the aid of realistic patient breast three-dimensional models, the variation in RI for different regions of tissue under investigation is shown to influence the estimation of optical properties in image-guided diffuse optical tomography (IG-DOT) using numerical simulations. It is also shown that by assuming identical RI for all regions of tissue would lead to erroneous estimation of optical properties. The a priori knowledge of the RI for the segmented regions of tissue in IG-DOT, which is difficult to obtain for the in vivo cases, leads to more accurate estimates of optical properties. Even inclusion of approximated RI values, obtained from the literature, for the regions of tissue resulted in better estimates of optical properties, with values comparable to that of having the correct knowledge of RI for different regions of tissue.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new scheme is proposed for the detection of premature ventricular beats, which is a vital function in rhythm monitoring of cardiac patients. A transformation based on the first difference of the digitized electrocardiogram (ECG) signal is developed for the detection and delineation of QRS complexes. The method for classifying the abnormal complexes from the normal ones is based on the concepts of minimum phase and signal length. The parameters of a linear discriminant function obtained from a training feature vector set are used to classify the complexes. Results of application of the scheme to ECG of two arrhythmia patients are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For biological experiments requiring manipulations under a microscope, it is necessary to have remote control for the manipulator. Available systems offer the required accuracy at a high cost. Passive micromanipulators are economical but are deficient in performance, the most serious defects being the inability to attenuate operator-induced vibrations and lack of speed control The manipulator described in this paper provides versatile remote control and may be constructed economically.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Homomorphic analysis and pole-zero modeling of electrocardiogram (ECG) signals are presented in this paper. Four typical ECG signals are considered and deconvolved into their minimum and maximum phase components through cepstral filtering, with a view to study the possibility of more efficient feature selection from the component signals for diagnostic purposes. The complex cepstra of the signals are linearly filtered to extract the basic wavelet and the excitation function. The ECG signals are, in general, mixed phase and hence, exponential weighting is done to aid deconvolution of the signals. The basic wavelet for normal ECG approximates the action potential of the muscle fiber of the heart and the excitation function corresponds to the excitation pattern of the heart muscles during a cardiac cycle. The ECG signals and their components are pole-zero modeled and the pole-zero pattern of the models can give a clue to classify the normal and abnormal signals. Besides, storing only the parameters of the model can result in a data reduction of more than 3:1 for normal signals sampled at a moderate 128 samples/s

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For biological experiments requiring manipulations under a microscope, it is necessary to have remote control for the manipulator. Available systems offer the required accuracy at a high cost. Passive micromanipulators are economical but are deficient in performance, the most serious defects being the inability to attenuate operator-induced vibrations and lack of speed control The manipulator described in this paper provides versatile remote control and may be constructed economically.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, a procedure is presented for the reconstruction of biological organs from image sequences obtained through CT-scan. Although commercial software, which can accomplish this task, are readily available, the procedure presented here needs only free software. The procedure has been applied to reconstruct a liver from the scan data available in literature. 3D biological organs obtained this way can be used for the finite element analysis of biological organs and this has been demonstrated by carrying out an FE analysis on the reconstructed liver.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biomedical engineering solutions like surgical simulators need High Performance Computing (HPC) to achieve real-time performance. Graphics Processing Units (GPUs) offer HPC capabilities at low cost and low power consumption. In this work, it is demonstrated that a liver which is discretized by about 2500 finite element nodes, can be graphically simulated in realtime, by making use of a GPU. Present work takes into consideration the time needed for the data transfer from CPU to GPU and back from GPU to CPU. Although behaviour of liver is very complicated, present computer simulation assumes linear elastostatics. One needs to use the commercial software ANSYS to obtain the global stiffness matrix of the liver. Results show that GPUs are useful for the real-time graphical simulation of liver, which in turn is needed in simulators that are used for training surgeons in laparoscopic surgery. Although the computer simulation should involve rendering also, neither rendering, nor the time needed for rendering and displaying the liver on a screen, is considered in the present work. The present work is just a demonstration of a concept; the concept is not really implemented and validated. Future work is to develop software which can accomplish real-time and very realistic graphical simulation of liver, with rendered image of liver on the screen changing in real-time according to the position of the surgical tool tip approximated as the mouse cursor in 3D.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the image reconstruction using the fan-beam filtered backprojection (FBP) algorithm with no backprojection weight from windowed linear prediction (WLP) completed truncated projection data. The image reconstruction from truncated projections aims to reconstruct the object accurately from the available limited projection data. Due to the incomplete projection data, the reconstructed image contains truncation artifacts which extends into the region of interest (ROI) making the reconstructed image unsuitable for further use. Data completion techniques have been shown to be effective in such situations. We use windowed linear prediction technique for projection completion and then use the fan-beam FBP algorithm with no backprojection weight for the 2-D image reconstruction. We evaluate the quality of the reconstructed image using fan-beam FBP algorithm with no backprojection weight after WLP completion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Intra-aortic balloon pumping is a counter pulsation technique for temporary circulatory assistance in cardiogenic shock and other low cardiac output conditions. Conventional systems use a balloon at the end of a catheter driven by a solenoid valve, controlled by patient's ECG or ventricular pressure signal. This results in time delay introducted by solenoid spool inertia, gas inertia, and hysteresis effects of the solenoid. Fluidics, because of their non-moving part operation and high switching speeds, minimizes the inertial effects while contributing high reliability. This communication describes a fluidic system developed for driving the balloon accepting electric control signals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Surface chemistry and the intrinsic porous architectures of porous substrates play a major role in the design of drug delivery systems. An interesting example is the drug elution characteristic from hydrothermally synthesised titania nanotubes with tunable surface chemistry. The variation in release rates of Ibuprofen (IBU) is largely influenced by the nature of the functional groups on titania nanotubes and pH of suspending medium. To elucidate the extent of interaction between the encapsulated IBU and the functional groups on titania nanotubes, the release profiles have been modelled with an empirical Hill equation. The analysis aided in establishing a probable mechanism for the release of IBU from the titania nanotubes. The study of controlled drug release from TiO2 has wider implication in the context of biomedical engineering. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this text we present the design of a wearable health monitoring device capable of remotely monitoring health parameters of neonates for the first few weeks after birth. The device is primarily aimed at continuously tracking the skin temperature to indicate the onset of hypothermia in newborns. A medical grade thermistor is responsible for temperature measurement and is directly interfaced to a microcontroller with an integrated bluetooth low energy radio. An inertial sensor is also present in the device to facilitate breathing rate measurement which has been discussed briefly. Sensed data is transferred securely over bluetooth low energy radio to a nearby gateway, which relays the information to a central database for real time monitoring. Low power optimizations at both the circuit and software levels ensure a prolonged battery life. The device is packaged in a baby friendly, water proof housing and is easily sterilizable and reusable.